Fusible Plugs

 

Fusible Plugs

***

3d printable fusible plugs 

***
Relevant Background: Metals and alloys have a variation in melting point temperature... Metal alloy samples may be used to test fusible plugs for a specific application.
****

Materials: 


b) Bronze (Corrosion resistant undersea/salty water for marine applications, non-flammable, non-combustible and reusable with a melting point range of 854 - 1010 degree celsius): "Bronze is a copper-tin alloy with a deep red color (similar to rose gold) commonly used in jewelry, accessories, and home decor"



















*******************************************
Applications: 

2. Container ships transporting hazardous chemicals and substances as well as Freight Trains and Rail cars for hazardous material transport. For example, transportation of Chlorine and Acetylene...






6. Industrial Boiler Room Supplies
*******
Other Applications:  Calculator, Periodic Table, Dictionary, Audiobook, Software tutorials, Excel Templates, Material Sample, Gaming Content, Apps, Material Test
***********************************************************
Relevant Background on Fusible Plugs: "A fusible plug is a threaded metal cylinder usually of bronze, brass or gunmetal, with a tapered hole drilled completely through its length. This hole is sealed with a metal of low melting point that flows away if a pre-determined, high temperature is reached. The initial use of the fusible plug was as a safety precaution against low water levels in steam engine boilers, but later applications extended its use to other closed vessels, such as air conditioning systems and tanks for transporting corrosive or liquefied petroleum gasses....A fusible plug operates as a safety valve when dangerous temperatures, rather than dangerous pressures, are reached in a closed vessel. In steam engines the fusible plug is screwed into the crown sheet (the top plate) of the firebox, typically extending about an inch (25mm) into the water space above it. Its purpose is to act as a last-resort safety device in the event of the water level falling dangerously low: when the top of the plug is out of the water it overheats, the low-melting-point core melts away and the resulting noisy release of steam into the firebox serves to warn the operators of the danger before the top of the firebox itself runs completely dry, which could result in catastrophic failure of the boiler. The temperature of the flue gases in a steam engine firebox can reach 1000 °F (550 °C), at which temperature copper, from which historically most fireboxes were made, softens to a state which can no longer sustain the boiler pressure and a severe explosion will result if water is not put into the boiler quickly and the fire removed or extinguished.[1] The hole through the plug is too small to have any great effect in reducing the steam pressure and the small amount of water, if any, that passes through it is not expected to have any great impact in quenching the fire...The original design was a simple solid plug filled with a slug of low-melting-point alloy. When this melts, it first melts as a narrow channel through the plug. Steam and water immediately begins to escape through this. The cored fusible plug was developed in the 1860s to give a wide opening as soon as the alloy softens. This version has a solid brass or bronze centre, soldered into place by a layer of the low-melting-point alloy. When overheated, the plug does not release any steam or water until the alloy melts sufficiently to release the centre plug. The plug now fails dramatically, opening its entire bore immediately. This full-bore jet is then more likely to be noticed....Investigation showed the importance of the alloy on plug ageing. Alloys were initially favoured as they offered lower eutectic melting points than pure metals. It was found though that alloys aged poorly and could encourage the development of a matrix of oxides on the water surface of the plug, this matrix having a dangerously high melting point that made the plug inoperable. In 1888 the US Steamboat Inspection Service made a requirement that plugs were to be made of pure banca tin and replaced annually... This avoided lead and also zinc contamination. Zinc contamination was regarded as so serious a problem that the case of the plugs was also changed from brass (a copper-zinc alloy) to a zinc-free copper-tin bronze, to avoid the risk of zinc migrating from the housing into the alloy plug...The principle of the fusible plug is also applied to the transport of liquefied petroleum gases, where fusible plugs (or small, exposed patches of the containers' lining membrane) are designed to melt or become porous if too high a temperature is reached: a controlled release, at a typical temperature of 250 °F (120 °C), is preferable to an explosive release (a "BLEVE") at a higher temperature...Corrosive gas containers, such as those used for liquid chlorine, are fitted with one or more fusible plugs with an operating temperature of about 158 to 165 °F (70–74 °C)....Fusible plugs are common in aircraft wheels, typically in larger or high-performance aircraft. The very large thermal loads imposed by abnormal landing and braking conditions (such as a high-speed rejected takeoff, where an aircraft heavy with fuel must brake hard from a very high speed to a stop in a relatively short distance) can cause the already high pressure in the tyres to rise to the point that the tyre might burst, so fusible plugs are used as a relief mechanism. The vented gas may be directed to cool the braking surfaces....Fusible plugs are sometimes fitted to the receivers of air compressors as a precaution against the ignition of any lubricating oil vapour that might be present. Should the action of the compressor heat the air above a safe temperature the core will melt and release the pressure...Automobile air conditioning systems were commonly fitted with fusible plugs, operating at 100–110 °C, but from concerns about the environmental effects of any released refrigerant gas this function has been taken over by an electrical switch....A patented (Patent published 1867) type of fireproof safe uses a fusible plug to douse its contents with water if the external temperature gets too high..." (Fusible Plugs", https://en.wikipedia.org/wiki/Fusible_plug)

***
Relevant Background on Fusible Plugs in Aircraft: "Aircraft tires also include fusible plugs (which are assembled on the inside of the wheels), designed to melt at a certain temperature. Tires often overheat if maximum braking is applied during an aborted takeoff or an emergency landing. The fuses provide a safer failure mode that prevents tire explosions by deflating in a controlled manner, thus minimizing damage to aircraft and objects in the surrounding environment." ("Aircraft Tire", https://www.wikiwand.com/en/Aircraft_tire)
*****************
Relevant Background for application in Transportation -- Fusible plugs in Transportation: "The principle of the fusible plug is also applied to the transport of liquefied petroleum gases, where fusible plugs (or small, exposed patches of the containers' lining membrane) are designed to melt or become porous if too high a temperature is reached: a controlled release, at a typical temperature of 250 °F (120 °C), is preferable to an explosive release (a "BLEVE") at a higher temperature. Corrosive gas containers, such as those used for liquid chlorine, are fitted with one or more fusible plugs with an operating temperature of about 158 to 165 °F (70–74 °C)." ("Fusible plug", https://en.wikipedia.org/wiki/Fusible_plug)
********************************
Relevant material for Fusible plug use in Hazardous Materials Transportation & Storage: "Most cylinders have one or more safety-relief devices. These devices can prevent rupture of the cylinder if internal pressure builds up to levels exceeding design limits. Pressure can become dangerously high if a cylinder is exposed to fire or heat, including high storage temperatures. There are three types of safety-relief devices. Each relieves excessive gas pressures in a different way...Safety- or Pressure-Relief Valves: These valves are usually a part of the cylinder. They are normally held closed by a spring. The force holding the valve closed is set according to the type of gas in the cylinder. The valve opens if the cylinder pressure exceeds the set safety limit. Gas is released until the cylinder pressure drops back to the safety limit. The valve then closes and retains the remaining gas in the cylinder....Rupture Discs (also known as frangible or bursting discs): These discs are usually made from metal. They burst or rupture at a certain pressure, releasing the gas in the cylinder. The bursting pressure is designed so that the disc ruptures before the cylinder test pressure is reached. These devices cannot be reclosed, so the entire contents of the cylinder are released. ("How Do I Work Safely with - Compressed Gases", https://www.ccohs.ca/oshanswers/prevention/comp_gas.html)
******************
Fusible Plugs (also called fuse or melt plugs): Temperature, not pressure, activates fusible plugs. These safety devices are used where heat could initiate an explosive chemical reaction. A pressure-relief valve or rupture disc acts too slowly and too late to prevent rupture of the cylinder if an explosive reaction has already begun. The fusible plug releases the gas before the hazardous reaction can begin. Fusible plugs are made of metals that melt at low temperatures. For example, acetylene cylinders have a fusible plug which melts at about 100°C (212°F). This temperature is safely below the temperature at which hazardous polymerization may occur. Not all compressed gas cylinders have safety devices. Some gases are so toxic that their release through a safety device would be hazardous. Cylinders for these gases are built to withstand higher pressures than normal cylinders. When these "toxic gas" cylinders are involved in a fire, the area must be evacuated." ("How to Work Safely with - Compressed Gases", https://www.ccohs.ca/...)
*******************************************
Relevant Material on Fusible plugs application in Fire Sprinkler Systems: "In an automatically controlled fire protection system, fusible plugs are typically used as detection devices. These are devices installed as closed sprinklers on the pilot line, that melt or break when temperatures reach 60˚C or more. When broken, they activate/open the sprinklers which in result release the pilot line pressure." ("Deluge Valves: Hydraulic vs. Pneumatic Fusible Pilot Lines", https://blog.bermad.com/fire-protection/deluge-valves-fusible-pilot-line-hydraulic-vs.-pneumatic...)

** 